Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Nephrol ; 24(1): 245, 2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37608357

RESUMO

BACKGROUND: On December 29, 2021, during the delta wave of the Coronavirus Disease 2019 (COVID-19) pandemic, the stock of premanufactured solutions used for continuous kidney replacement therapy (CKRT) at the University of New Mexico Hospital (UNMH) was nearly exhausted with no resupply anticipated due to supply chain disruptions. Within hours, a backup plan, devised and tested 18 months prior, to locally produce CKRT dialysate was implemented. This report describes the emergency implementation and outcomes of this on-site CKRT dialysate production system. METHODS: This is a single-center retrospective case series and narrative report describing and reporting the outcomes of the implementation of an on-site CKRT dialysate production system. All adults treated with locally produced CKRT dialysate in December 2021 and January 2022 at UNMH were included. CKRT dialysate was produced locally using intermittent hemodialysis machines, hemodialysis concentrate, sterile parenteral nutrition bags, and connectors made of 3-D printed biocompatible rigid material. Outcomes analyzed included dialysate testing for composition and microbiologic contamination, CKRT prescription components, patient mortality, sequential organ failure assessment (SOFA) scores, and catheter-associated bloodstream infections (CLABSIs). RESULTS: Over 13 days, 22 patients were treated with 3,645 L of locally produced dialysate with a mean dose of 20.0 mL/kg/h. Fluid sample testing at 48 h revealed appropriate electrolyte composition and endotoxin levels and bacterial colony counts at or below the lower limit of detection. No CLABSIs occurred within 7 days of exposure to locally produced dialysate. In-hospital mortality was 81.8% and 28-day mortality was 68.2%, though illness severity was high, with a mean SOFA score of 14.5. CONCLUSIONS: Though producing CKRT fluid with IHD machines is not novel, this report represents the first description of the rapid and successful implementation of a backup plan for local CKRT dialysate production at a large academic medical center in the U.S. during the COVID-19 pandemic. Though conclusions are limited by the retrospective design and limited sample size of our analysis, our experience could serve as a guide for other centers navigating similar severe supply constraints in the future.


Assuntos
COVID-19 , Infecções Relacionadas a Cateter , Terapia de Substituição Renal Contínua , Adulto , Humanos , Soluções para Diálise , Pandemias , Estudos Retrospectivos
2.
Ren Replace Ther ; 7(1): 43, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34367669

RESUMO

In May and June 2020, an outbreak of methanol poisoning arose in the southwest United States linked to ingestion of contaminated hand sanitizer imported during the coronavirus disease 2019 pandemic, ultimately resulting in over a dozen hospitalizations and at least four deaths in New Mexico and Arizona. In this report, we describe one of these cases in which profound methanol intoxication was successfully treated with the Tablo® Hemodialysis System, the first reported case of toxic alcohol poisoning treated with this novel device. We carry out a formal regression analysis of the serial methanol levels obtained in this case to conservatively estimate that intermittent hemodialysis with Tablo achieved a clearance of methanol of 239 mL/min (95% confidence interval, 173-305 mL/min), a clearance that is well within the previously published standard of care. We conclude by reviewing both the treatment of toxic alcohol poisoning and the determinants of small molecule clearance with hemodialysis, emphasizing the importance of optimizing the dialytic treatment of intoxications with extended treatment times and the use of high-efficiency dialyzers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...